SR141CTP
Semi-rigid .141 (3.6mm) Tin-plated Copper Non-magnetic Center Conductor
| Electrical |
| Impedance (Ω) | 50 Ohms |
| Effective Frequency | 35 |
| Velocity of Propagation | 70 |
| Shielding Effectiveness | >100 |
| Capacitance | 29 pF/ft |
| Mechanical |
| Minimum Bend Radius | 0.15 in |
| Weight | 0.030 lbs/ft |
| Cable Layer |
Diameter In. (mm) |
Cable Material |
| Center Conductor |
0.036 |
SPC (Silver-plated Copper Wire) |
| Dielectric |
0.1175 |
PTFE (Polytetrafluoroethylene) |
| Inner-shield |
0.141 |
Tin-plated Copper |
| Outer-shield |
N/A |
N/A |
| Outer-jacket |
N/A |
N/A |
| Sample Frequency (GHz) |
Assembly Insertion Loss (dB/100ft) |
Power Handling (Watts-Typical) |
| 0.5 |
N/A |
N/A |
| 1 |
11.06 |
421.94 |
| 2 |
16.12 |
286.44 |
| 3 |
20.19 |
233.88 |
| 4 |
23.74 |
202.54 |
| 6 |
29.97 |
165.37 |
| 8 |
35.47 |
143.22 |
| 11 |
42.90 |
122.14 |
| 12 |
45.60 |
116.94 |
| 18 |
57.86 |
92.77 |
| 26.5 |
73.90 |
73.71 |
| 32 |
83.60 |
66.90 |
| 40 |
N/A |
N/A |
| 50 |
N/A |
N/A |
| 65 |
N/A |
N/A |