Print specification

SR086-SB-B

Semi-rigid .086" (2.19mm) Silver Plated BeCu Center Conductor - Bare BeCu Outer Conductor

SR086-SB-B
Electrical
Impedance (Ω)50 Ohms
Effective Frequency65
Velocity of Propagation70%
Shielding Effectiveness-110 dB
Capacitance29 pF/ft
Mechanical
Minimum Bend Radius0.125 in
Weight0.013 lbs/ft
Cable Layer Diameter In. (mm) Cable Material
Center Conductor 0.0201 Silver-Plated High Strength Copper Alloy
Dielectric 0.066 PTFE (Polytetrafluoroethylene)
Inner-shield 0.086 Beryllium Copper Alloy
Outer-shield N/A N/A
Outer-jacket N/A N/A
Sample Frequency (GHz) Assembly Insertion Loss (dB/100ft) Power Handling (Watts-Typical)
0.5 N/A N/A
1 29.78 131.41
2 40.12 89.21
3 47.10 72.84
4 53.82 63.08
6 65.60 51.51
8 78.84 44.61
11 88.21 38.04
12 92.65 36.42
18 116.22 28.89
26.5 143.72 22.96
32 160.36 20.84
40 183.92 17.99
50 214.02 15.72
65 253.57 13.04